Filter Results By:

Products

Applications

Manufacturers

Showing results: 2881 - 2895 of 3394 items found.

  • Phasing Voltmeter/Sensor (2 in 1)

    STB Electrical Test Equipment, Inc

    STB unit replaces 3 separate units manufactured by competitors - line phasing, capacitance phasing and line to ground Versatile, lightweight and easy to useEach portable meter has a single rangeMeter usage: Voltage detection and phasing at capacitance test points or voltage detection and phasing on bare energized conductors (overhead & underground)Probes can be separated to be used as a voltage sensor or capacitance sensorFive position selector switch used to select voltage sensing on capacitance tap or direct line and phasing on capacitance tap, direct line or a battery test positionNo exposed conducting terminals or meter circuitryLocking cable connector provides positive contactScale is large enough to be easily read 8'-10' when mounted on a suitable hot stickLine to ground voltage readings are accurate within 3% at full scaleMaximum operating temperature range -20°F to 165°F (-30°C to 75°C)25' coiled cable includedAccessoriesMODELDESCRIPTION50118-G-10Hot Sticks (full set - 6)10104-P-02Shepherd's Hook10104-P-03Probe Tip30142-P-01Shot Gun Adapter50111-P-01Regular Bushing Adapter10275-P-01Universal AdapterModelsMODELDESCRIPTIONWeight50101-G-07Phasing Voltmeter 9-36kV16 lbs.50101-G-08Phasing Voltmeter 9-36kV with Hot Sticks (full set - 6)21 lbs.Request QuoteOperating Instructions9-36kV Phasing VoltmeterProduct Summary/OptionsProvides safe and convenient testing means for paralleling 3-phase high voltage circuitsConsists of two resistance elements connected in series with an indicating meter in the series connectionTwo ranges, 9kV and 36kV, with a range selector switch mounted on the back of the meter housingSwitch is clearly marked for the range of the voltmeterTypical use: Line-to-ground voltage measurements and phase for paralelling operationsScale markings on the voltmeter have a minimum of divisions and the figures are large enough to be easily read 8'-10' away when mounted on a suitable hot stickInput impedance: Approximately 72 megohmsMaximum operating temperature range -20°F to 165°F (-30°C to 75°C)Ready to attach on hot stick10' cable, a proof tester, battery and shepherd’s hook and probe tip includedOperating InstructionsRequest QuoteOperating InstructionsModelsMODELDESCRIPTION50100-G-010-2kV DC Voltmeter 30’ cable, magnetic track adapter50100-G-020-1500kV DC Voltage Meter50100-G-030-1500kV DC Voltage Meter with Hot Sticks50100-G-04DC Voltmeter 1500kV DC w/Extension Probe and Ground Lead50100-G-050-1500V DC with Hot Sticks and Lighted Dial50100-G-060-1500 DC Voltage Meter with Lighted DialDC Voltmeter​Product Summary/OptionsLightweight, easy to use, hand-held meterHard wired unit Scaled 0-1500vDC, in 100 volt incrementsProvides a 2/3 full scale deflection when applied across 1000vDCMaximum current flow through instrument at 1000vDC is 0.05 milliampersNo polarity, sensitivity issuesMay be used to determine whether the third rail of a transit system is energizedInput impedance of approximately 24 megohmMaximum operating temperature range -20°F to 165°F (-30° C to 75°C) Request QuoteAC VoltmeterProduct Summary/OptionsTwo-position toggle switchPortable instrument for quickly and easily measuring AC voltages Locking cable connector provides positive, electrical contactResistive voltmeter - medium range voltage measurements in the fieldTypical use - measure voltage between ground and the line or bus connector20' ground lead includedInput impedance - approximately 36 meghomsMaximum operating temperature rangeAccuracy of +/- 3% full scaleShare to TwitterShare to FacebookShare to PrintShare to EmailMore AddThis Share options

  • Cell Stand

    CS-3A - ALS Co., Ltd

    The CS-3A Cell Stand is adopted with CHI series Electrochemical Analyzers and other apparatus directly. The cell is enclosed in a Faraday cage to reduce electrical interference. A built-in gas control allows purging a sample. Gas line is provided to purge next sample, while analyzing the present sample separately, thus increasing productivity. Magnetic stirrer allows for controlling the mixing of the sample for experiments requiring mass transport of electrolyte or analyte to the electrode surface. Cell top positioner with detachable cell cap allows easy removal and replacement of the cell vial as well as the electrodes for rinsing, cleaning, and replacement.

  • Extractive Gas Analyzers

    Advance Optima and EasyLine Series - ABB Ltd.

    ABB offers three series of extractive gas analyzers catering to a diverse range of industries and applications. Sensing technologies perfected over more than 90 years are the foundation for a modular architecture delivering market leading performance and reliability – Uras (NDIR), Limas (NDUV), Magnos (Paramagnetic), Caldos (TCD), Fidas (FID), ZO23 (Zirconia). ABB also offers tunable diode laser (TDL) analyzers that measure in situ, directly at the stack or process line. The analyzers are world renowned for ruggedness, easy installation and operation in safe and hazardous areas, simplified calibration and outstanding possibilities for integration in digital networks.

  • Hazardous Location Sensors

    S88 - Electro-Chemical Devices

    The S88 pH Sensors are one part of the Model S88 Intelligent Sensors product line. The S88 Sensors offering includes pH Sensors, ORP Sensors, Ion Selective Sensors, Dissolved Oxygen Sensors, Conductivity Sensors and Resistivity Sensors. The S88 sensors have two Universal Sensor Designs; Insertion/Submersion or Valve Retractable with flared end to prevent blow out. The standard S88 sensors have 316 Stainless Steel housings although various materials of construction are available to maximize sensor performance while minimizing cost of ownership. For other materials of construction request a quotation from the factory.

  • High Frequency Current Transformer

    HFCT Ø 140mm - Techimp HQ S.r.L

    Techimp Clamp High Frequency Current Transformer model 140 is an inductive sensor for partial discharge measurements. It is suitable for online /off line PD tests on : large diameter cables ; grounding rod bar ; etc. A TNC termination is available to connect the Clamp HFCT 140 to the TechImp PD analyzer : PDCheck , PDBase etc. The arrow indicates the requested input current (Iin) direction to get coherent output voltage (Vout) polarity respect to ground. When the sensor is installed with the arrow directed to ground, the detected voltage signal (Vout) has the same phase of the input current (Iin).

  • Hyperspectral Imaging Sensors

    Headwall Photonics, Inc.

    HYPERSPEC® sensors are line-scanning instruments (sometimes called pushbroom) that collect reflected light through an image slit. One row of spatial pixels is collected per frame as motion occurs, with each pixel containing full spectral data. Motion can be accomplished in two ways: either as an airborne deployment (UAV, aircraft, or satellite) or stationary (where motion is accomplished beneath the sensor, such as a food inspection line). A third option is also available where pan-and-tilt or rotary stages allow a fixed-location sensor to scan a stationary object (such as a piece of artwork, or a mine face for geological applications).

  • Process Timers

    TCT101-1ABC - Datexel

    The Process Timer TCT101-1ABC is a panel mount 4 digit 2 line display meter that can be set up for various Timer functions, such as Timer Off, Timer On, Pause Timer, Timer On and Off, Propotinal Timer. The TCT101-1ABC has 2 relays that can be used for various functions and has 5 Amp contacts. The timer periods can be set in multiples of 1 hundredths, 1 tenths of a second, seconds, minutes or hours. With the aid of the front touch panel or digital input it is possible to interrupt the timer. The unit also has a function that can set the output to toggle on and off over a period of time.

  • Serial I/O Boards

    General Standards Corporation

    Serial Mode Protocols include Asynchronous, Bisync, SDLC, HDLC, IEEE 802.3, Synchronous Telemetry, Simple Clock/Data ("-SYNC" product line), Di-phase and SPI Interface. Transceiver support RS485, RS422 (V.10), RS232 (V.28), RS423, V.35, RS530, as well as other software selectable mixed protocol modes Up to Eight Independent Serial Channels per Board Synchronous Serial Data Rates up to 10 Mbits/sec Asynchronous Serial Data Rates up to 1 Mbits/sec PMC and cPCI rear I/O support Custom Protocols Available

  • Software

    FDCS - Mesuro Ltd

    Beyond traditional Noise and Harmonic Load/Source Pull, FDCS also supports Tuner and Fixture (TRL) calibrations, Time Domain Load Line acquisition, Pulsed IV and Load Pull and Active feedback Power Injection operations (for Γ ≥ 1).The measured data are processed graphically into 2D and 3D plots and are converted into popular simulator formats (ADS, AWR etc.).The FDCS user unterface includes many many improvements and optimizations to make load pull and noise measurement easier.The software has ActiveX control for controlling MPT tuners in any ActiveX compatible platform.

  • Software

    Focus Microwaves

    Beyond traditional Noise and Harmonic Load/Source Pull, FDCS also supports Tuner and Fixture (TRL) calibrations, Time Domain Load Line acquisition, Pulsed IV and Load Pull and Active feedback Power Injection operations (for Γ ≥ 1).The measured data are processed graphically into 2D and 3D plots and are converted into popular simulator formats (ADS, AWR etc.).The FDCS user unterface includes many many improvements and optimizations to make load pull and noise measurement easier.The software has ActiveX control for controlling MPT tuners in any ActiveX compatible platform.

  • True RMS Digital Insulation Multimeter

    Model KM 877 - Kusam Electrical Industries Limited

    • VFD V & Hz readings.• Paper White Backlight LCD Display• Record MAX / MIN readings.• Display Hold Function.• Dual Digital Display.• PI & DAR Function.• Autoranging.• Pass /Fail Insulation Resistance Compare function; 12 selectable Preset Values.• LOCK-Test mode for Insulation Resistance & Earth Continuity Test.• BeepJack ™ audible & visible input warning.• Remote Probe for insulation Resistance & Earth Continuity Test.• Functions : DC/AC Voltage , VFD AC Voltage, Insulation Resisitance, Resistance, Earth Continuity Test, Hz Line Level Frequency

  • Shielding Effectiveness/ Conductivity Test

    EM-2107A | 30 MHz – 1.5 GHz - Electro-Metrics Corp.

    The EM-2107A is a standard test fixture for evaluation of the electromagnetic shielding effectiveness of planar material. The fixture is an enlarged section of coaxial transmission line and complies fully with the requirements of ASTM test method D4935-1. The measured data relates to the shielding effectiveness due to a plane wave (far field EM wave) from which near field values for magnetic and electric fields may be inferred. The EM-2107A is provided with a reference standard test specimen, a dynamic range specimen. Dynamic range of greater than 80dB is achievable, although the cables and other test system components usually establishes the limiting factors.

  • Field Test Set

    MTS-207 - Terotest Systems Ltd.

    The MTS-207 is a state-of-the-art portable PXI platform for field testing and data acquisition systems. Its proven architecture has been deployed worldwide on multiple programs including the MTS-206 Maverick Missile system flight line tester. The MTS-209 Common Armament Test Set, the AN/TSM-205B Hellfire System test Set, and many more. It combines the capabilities of the versatile and powerful PXI architecture in a compact, ultra-rugged, flight-line qualified enclosure. The MTS-207 is ideal for test and data acquisition applications requiring operation under harsh environmental conditions including flight-line, back-shop, or airborne applications.

  • PXI Analog Output Module

    NI

    PXI Analog Output Modules support both static and software-timed voltage output applications. Modules also include 5 V TTL/CMOS digital I/O lines. Some PXI Analog Output Modules can deliver simultaneous, multichannel updates for control and waveform output applications, such as stimulus-response, power supply control, high-speed, deterministic control, and sensor/signal simulation. These advanced features enable you to use the PXI Analog Output Module to replace several kinds of instruments, including stand-alone proportional integral derivative (PID) controllers, low-speed arbitrary waveform generators, and function generators.

  • Rugged Field Test Set

    MTS-207 - Marvin Test Solutions, Inc.

    The MTS-207 is a state-of-the-art portable PXI platform for field testing and data acquisition systems. Its proven architecture has been deployed worldwide on multiple programs including the MTS-206 Maverick Missile system flight line tester, the MTS-209 Common Armament Test Set, the AN/TSM-205B Hellfire System test Set, and many more. It combines the capabilities of the versatile and powerful PXI architecture in a compact, ultra-rugged, flightline qualified enclosure. The MTS-207 is ideal for test and data acquisition applications requiring operation under harsh environmental conditions including flightline, back-shop, or airborne applications.

Get Help